**CO2 Incubator Operating Instructions and Company Introduction** 1. The CO₂ incubator must not be turned on before water is added to the tank, as this could damage the heating element. 2. After several months of use, the water level in the tank may decrease due to evaporation. When the low water level indicator lights up, water should be added immediately. First, open the overflow pipe and connect a funnel with a rubber tube to fill the tank through the water inlet until the low water level light turns off. Measure the amount of water added, then close the overflow pipe. 3. If the CO₂ incubator is used as a high-precision constant temperature incubator, the CO₂ control system must be turned off. 4. Since the CO₂ sensor is calibrated under saturated humidity, the humidifying tray must always be filled with sterilized water. 5. If the display temperature exceeds the set temperature by 1°C, the over-temperature alarm will sound and the indicator light will turn on. At this point, the power should be turned off for 30 minutes. If the temperature remains over the limit, turn off the power and contact maintenance personnel. 6. Replace the gas cylinder when the pressure drops below 0.2MPa. 7. Minimize the time the glass door is left open to maintain internal conditions. 8. If the CO₂ incubator is not in use for an extended period, remove all moisture from the working chamber. Open the glass door and ventilate for 24 hours before closing it. 9. When cleaning the incubator, avoid hitting the sensor or the stirring motor fan to prevent damage. 10. When disassembling or assembling the internal support brackets, use a special wrench and avoid applying excessive force. 11. Before handling the incubator, drain the water from the tank. To do so, place the rubber tube tightly on the outlet hole, position the nozzle lower than the device, gently suck to start the siphon, and let the water drain out. 12. Before moving the incubator, remove the shelves and humidifying tray from the working chamber to prevent damage to the glass door. 13. Do not invert the incubator during transport, and avoid lifting the door to prevent deformation. --- Shangyu Xingxing Instrument Equipment Co., Ltd. is located in Daoxu Town, Shangyu District, Shaoxing City, Zhejiang Province. It is a company that integrates production, product development, processing, and trade. The company's main products include drying ovens, incubators, laboratory muffle furnaces, distillation units, as well as clean benches, air showers, fume hoods, and biological safety cabinets—offering complete purification equipment solutions. The company has a strong technical research and development team and a comprehensive after-sales service system. As a leading manufacturer in China’s laboratory equipment industry, we welcome customers to visit and purchase our products. With years of experience and a commitment to quality, we are dedicated to providing reliable and efficient laboratory solutions. Whether you're setting up a new lab or upgrading existing equipment, we are here to support your needs. ![Image](http://i.bosscdn.com/blog/20/17/10/211725766230.jpg) ![Image](http://i.bosscdn.com/blog/20/17/10/2117258439716.jpg)

Differential Mode Inductor

Differential Mode Ring Inductance,Differential Mode Inductor Series,Differential Mode Filter Inductor,Differential-mode choke

Xuzhou Jiuli Electronics Co., Ltd , https://www.xzjiulielectronic.com